  • Product Description
Overview
Product Attributes

Model No.A30Ex

BrandCalstar

BrandCalstar

Weight122kg

Material Of Tank304 Stainless Steel

Power Supply220/50ACV/HZ

Cycle Time2.5Hr

Dimension825*638*1280 Mm

Type Of MachineSolvent Recovery Unit

Supply Ability & Additional Information

PackagingWooden box

Productivity500set

TransportationOcean

Place of OriginShenzhen, China

Supply Ability10 sets per day

CertificateISO14000,ISO9001,Ex,CE

PortShenzhen

Payment TypeL/C,T/T

IncotermFOB

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
Wooden box


A30Ex SUS304 essential oil ethanol solvent recovery unit

Product Introduction

A30Ex, specially designed solvent purification unit for small amount of organic solvent recovery. Tilting-type and air-cooled condensing system, safe structure are manufactured by Chinese explosion-proof standard (CNEX: Ex d IIB T2 Gb, certificate No. CNEx16.2110X) and European standard (ATEX). After distilling and cooling for proximate 2.5 hours, clean organic solvents will be ready for reuse.
It is suitable for small amount of organic solvent to recycle.

Product Photos

 IMG_8439aaIMG_8601


Detailed images

A30Ex_detail_3A30Ex_detail_4

Technical data

Imput volume
32 L
Length
825 mm
Capacity of Tank
46 L
Width
638 mm
Capacity of heat transfer oil
15.5 L
Height
1280 mm
Power of heater
4.0 KW
Weight
122 KG
Power of fan
0.09 KW
Temp. of operation
50~190 °C
Max power
4.2 KW
Ideal room temp.
5~30 °C
Max current
19.1 A
Noise
around 65 db
Power supply
220V AC/50 HZ
Voltage of control unit
24V DC
Heating method
Indirect heating by heat transfer oil
Cycle time
around 2.5 Hours
Recovery rate
95%
Cooling system
Air-cooled
Solvent imput
Manual ( automatic imput unit is addable)
Material of case
Carbon steel with paint, or SUS304
Vacuum unit
None(option addable)
Material of tank
SUS304, double layers

NOTE: Values listed above are under ideal conditions in laboratory, just for your reference. The realistic data will be a little deviation due to the difference of waste content, boiling point of solvent, room temperature, viscosity etc.

Recoverable solvents list
1. Aromatics categories: toluene, xylene, mesitylene, etc.
2. Aliphatic hydrocarbons: pentane, hexane, octane, etc.
3. Alicyclic hydrocarbons : cyclohexane, cyclohexanone, toluene and cyclohexanone, etc.
4. Halogenated hydrocarbons: chlorobenzene, dichlorobenzene, methylene chloride, trichlorethylene, etc.
5. Alcohols: methanol, ethanol, isopropyl alcohol, etc. 
6. Ether: ether, propylene oxide, etc.
7. Esters: methyl acetate, ethyl acetate, butyl acetate, etc.
8. Ketone: acetone, methyl ethyl ketone, methyl isobutyl ketone, etc.
9. As well as other organic solvents that are not listed.

Unrecoverable solvents list

1. Nitrocellulose (nitro), and oxidant solvents and other hazardous materials.
2. Strong acid or strong alkaline solvents.
3. Highly toxic solvents.
4. Pairs of stainless steel or brass with a strong corrosive solvent.

Main Features

Explosion-proof design: in compliance with Chinese Explosion-proof standards (CNEX) and European standards (ATEX), 
Standardized production, stable and durable quality guaranteed.
Tilting-type: gradually tilting and pouring out waste residue which is easily removed.
SUS304 stainless steel tank is used to prevent chemical corrosion. Two layers design, reinforcement barrelhead design, precise temperature control, explosion-proof, anti-leakage are made for safer operation.
Heating Method: heat medium (heat transfer oils) indirect heating.
Digital heating temperature controller: advanced numerical display, accurate and convenient heating temperature control.
Multiple operational safety protection functions: power off or power on by timing or temperature pre-set, excessive temperature protection features; high-voltage protection function; power failure protection function.
Short reclaiming process, simple operation.
Less maintenance. 

Packing and Delivery

Packing

1. Seaworthy standard wooden box.
Delivery
1. 15 days after payment if equipment in stock, or 30 days after payment if equipment customized.


Certifications

 A30_60_90certificates

Our clients

partners 

Our Service

1. Quick response within 3 hours.
2. Products with international certificate.
3. Products 100% QC checked before shipping.
4. Three-year warranty for completed machine except Heat transfer oil, Gaskets and switches.
5. Customization and Buyer label offered are available.
6. providing professional solution of solvent recovery.
7. providing solvent sample analysis and optimizing solvent formula for free.
8. Wholesale and retail.
9. Pre-sales inquiry and consulting.
10. On site installation and operation training after sales while Volume of machine is 200L equal or above. On the contrary, video of installation and operation training provided.

 




Product Categories : Solvent Recovery Machine > Air Cooled Solvent Recovery Machine

Email to this supplier
  • *Subject:
  • *To:
    Ms. Ge Wen Xia
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
HomeProductsSolvent Recovery MachineAir Cooled Solvent Recovery MachineA30Ex SUS304 essential oil ethanol solvent recovery unit
Send Inquiry
*
*

Home

Product

Phone

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send